JC Heading

Test Description: FZR 1000 J.C. Performance Stage III

5 Valve Stage III Flowbench data
(Stage IV is approx +10%)

Intake Valve Diameter: CONFIDENTIAL Intake Stem Diameter: 4.5mm
Exhaust Valve Diameter: CONFIDENTIAL Exhaust Stem Diameter: 4.5mm
Intake Area: Proprietary Exhaust Area: Proprietary
Barometric Pressure: 29.92 Altitude: 12
Barometric & Altitude Correction Factor: 1.0 Room Temperature: 60o


These numbers are much improved by using an 80mm Bore (1125cc)
Valve Lift/Diameter (L/D) .05 .1 .15 .2 .25 .3
Intake Value Lift
 
 
 
 
 
 
Exhaust Value Lift
 
 
 
 
 
 


* - 117 CFM with 39mm Carb
** - at full lift.
*** - 80% of modified intake with 39mm Carb
78mm Bore Intake & Manifold & Stack Exhaust & Mod. Primary Pipe
Test Number 1 2 3 4 5 6 7 8 9 10 11 12
Port Tested #3 #3 #3
 
#3
 
#3
 
 
 
 
 
Test Pressure
Inches H20
10" 9" 8"
 
6"
 
8"
 
 
 
 
 
Valve Lift Inches .100 .200 Full
Lift
.308
 
Custom
Cam
 
Full
.299
 
 
 
 
 
Flow Range Selected 76.8 97.9 131.3
 
131.3
 
86.2
 
 
 
 
 
Flow Gage Reading % 76 95.9 82.5
 
80.5
 
97.5
 
 
 
 
 
Corrected Flow @ 10"
Fr*Fg*Cf
58.3 CFM 100.69 CFM 121.07 CFM
 
136.3 CFM
 
93.9 CFM
 
 
 
 
 
Leakage 0 0 0
 
0
 
0
 
 
 
 
 
Test Flow
(Cf - Leakage)
 
 
 
 
 
 
 
 
 
 
 
 
Test Flow / In2
 
 
 
 
 
 
 
 
 
 
 
 
Theor. Max. Flow for Valve Area 38.59 CFM 76.9 106.6
 
106.6
 
***
 
 
 
 
 
% Max. Flow Achieved 152% 130% 114% *
 
128% **
 
***
 
 
 
 
 

Page created & maintained by JC, ...jeff@jcperformance-engines.com.