JC Heading

Test Description: Buell Thunderstorm XL1200 Head - J.C. Modified Head Exhaust

Intake Valve Diameter: Intake Stem Diameter:
Exhaust Valve Diameter: 1.575 Exhaust Stem Diameter: .310
Intake Area: Exhaust Area:
Barometric Pressure: 29.9" Altitude: 12'
Barometric & Altitude Correction Factor: Room Temperature:


Valve Lift/Diameter (L/D) .05 .1 .15 .2 .25 .3
Intake Value Lift
 
 
 
 
 
 
Exhaust Value Lift
 
 
 
 
 
 


Test Number 1 2 3 4 5 6 7 8
Port Tested Exhaust Valve
Test Pressure 10" 10" 10" 10" 8" 7" 7" 7"
Valve Lift Inches .100 .150 .200 .300 .400 .450 .500 .550
Flow Range Selected 31.5 54.5 77.9 99.4 99.4 99.4 99.4 99.4
Flow Gage Reading % 90 84.5 83 89 94 92 95 97
Corrected Flow @ 10"
Fr*Fg*Cf
28.3 46 64.6 88.5 104.5 109.3 112.8 115.2
Leakage
 
 
 
 
 
 
 
 
Test Flow
(Cf - Leakage)
 
 
 
 
 
 
 
 
Test Flow / In2
 
 
 
 
 
 
 
 
Theor. Max. Flow for Valve Area
 
 
 
 
 
 
 
 
% Max. Flow Achieved
 
 
 
 
 
 
 
 
Flow @ 25"
 
 
 
 
 
 
 
 

Page created & maintained by JC, jcperformance-engines.com.